Fully automated and integrated spectrophotometric determination of dissolved oxygen in seawater
ID:1430 Poster Presentation

2027-01-15 16:15 (China Standard Time)

Session:Session 67 - Marine Robotics and Systems for Ocean Science Applications

Abstract
The determination of dissolved oxygen (DO) in natural waters is critically important for assessing water quality, understanding the diffusion of atmospheric gases, the circulation of water masses, and studying biological and chemical reactions. The Winkler method is a well-established and conventional technique for measuring DO. However, the titration method and spectrophotometric method improved based on the Winkler principle require a significantly large amount of manual operations, multiple procedural steps, dispersed hardware, in addition to the necessity of conducting calculations for accurate results. To address these challenges, a process automation and software integration system has been developed to automate the manual operations for measuring DO. A 466 nm wavelength LED light source was used to construct a custom single-wavelength spectrophotometric detection system. Reagents and standard solutions were introduced using multiple syringe pumps, while the temperature of the flow cell was regulated with a cooling chip. Software was implemented to automate the process and facilitate data processing. Parallel samples were prepared only after pure water had been bubbled for at least 10 hours. With a total of 41 parallel samples measured on a single day, a repeatability of 0.15% relative standard deviation (RSD) was achieved. Over eleven consecutive days of measurements, the reproducibility was 0.5%. Comparison of parallel samples showed that the deviation between this automated method and the conventional manual spectrophotometric method for determining DO was within 2 μmol/L. The relative error of the determined value was 0.65%, as calculated by comparing the measured values with the theoretical oxygen concentration of saturated water at 24.4°C. The limit of detection of the developed device was determined to be 6 μmol/L by means of the standard curve calculation method.
 
Speaker
Yan Li Xiamen University

Author
Yan Li Xiamen University

    Important Dates

    • Jan 30

      2026

      Session / Event proposals open

    • Mar 31

      2026

      Session / Event proposals close
      (Extended to April 7)

    • Apr 30

      2026

      Session acceptance notifications

    • Apr 30

      2026

      Abstract submissions & registration open

    • Jun 30

      2026

      Abstract submissions close
      (Extended to July 21)

    • Aug 31

      2026

      Abstract acceptance notifications

    • Sep 15

      2026

      Scientific program released

    • Oct 15

      2026

      Early bird registration closes

    • Jan 12–15

      2027

      XMAS 2027